When modeling a cross-section prestressed by tendons, it might happen you have to change the shape of the cross-section. At that moment, some of the tendons might appear out of the section. 

If you start the calculation now, the software automatically warns you that some of your tendons are out of the section. The solution for this situation is pretty easy: If the tendons ought to be considered in the calculation just tick on the checkbox Don't exclude tendons. 